-40%

Phoenix Contact TRIO-PS/1AC/48DC/5 Power Supply 2866491

$ 10.45

Availability: 100 in stock
  • MPN: TRIO-PS/1AC/48DC/5
  • Condition: Pulled from control panel working.
  • All returns accepted: ReturnsNotAccepted
  • Brand: Phoenix Contact
  • Mounting Style: DIN Rail Mount
  • Nominal Current Rating: 5 A
  • Output Voltage Rating (DC): 48 V

    Description

    Product Description
    TRIO POWER power supplies with standard functionality
    TRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.
    The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
    Dimensions
    Width
    60 mm
    Height
    130 mm
    Depth
    152.5 mm
    Installation distance right/left
    0 mm / 0 mm
    Installation distance top/bottom
    50 mm / 50 mm
    Back to top
    Ambient conditions
    Degree of protection
    IP20
    Ambient temperature (operation)
    -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
    Ambient temperature (storage/transport)
    -40 °C ... 85 °C
    Max. permissible relative humidity (operation)
    95 % (at 25 °C, non-condensing)
    Climatic class
    3K3 (in acc. with EN 60721)
    Degree of pollution
    2
    Back to top
    Input data
    Nominal input voltage range
    100 V AC ... 240 V AC
    Input voltage range
    85 V AC ... 264 V AC (derating < 90 V AC: 2.5 % per Kelvin)
    Dielectric strength maximum
    300 V AC
    AC frequency range
    45 Hz ... 65 Hz
    Discharge current to PE
    < 3.5 mA
    Current consumption
    2.5 A (120 V AC)
    1.3 A (230 V AC)
    Nominal power consumption
    282 VA
    Inrush current
    < 15 A
    Mains buffering time
    > 15 ms (120 V AC)
    > 16 ms (230 V AC)
    Recommended breaker for input protection
    10 A ... 16 A (Characteristics B, C, D, K)
    Power factor (cos phi)
    0.96
    Type of protection
    Transient surge protection
    Protective circuit/component
    Varistor
    Back to top
    Output data
    Nominal output voltage
    48 V DC ±1 %
    Setting range of the output voltage (U
    Set
    )
    30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
    Nominal output current (I
    N
    )
    5 A (-25 °C ... 55 °C)
    Derating
    55 °C ... 70 °C (2.5%/K)
    Connection in parallel
    yes, for redundancy and increased capacity
    Connection in series
    yes
    Feedback voltage resistance
    60 V DC
    Protection against overvoltage at the output (OVP)
    < 60 V DC
    Max. capacitive load
    unlimited
    Active current limitation
    Approx 5.7 A (in the event of a short-circuit)
    Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
    < 2 % (change in load, dynamic 10 % ... 90 %)
    < 0.1 % (change in input voltage ±10 %)
    Residual ripple
    < 50 mV
    PP
    Output power
    240 W
    Typical response time
    < 1 s
    Peak switching voltages nominal load
    < 50 mV
    PP
    Maximum power dissipation in no-load condition
    7 W
    Power loss nominal load max.
    28 W
    Back to top
    General
    Net weight
    1.4 kg
    Operating voltage display
    Green LED
    Efficiency
    > 89 % (for 230 V AC and nominal values)
    MTBF (IEC 61709, SN 29500)
    > 1337000 h (40 °C)
    Insulation voltage input/output
    4 kV AC (type test)
    2 kV AC (routine test)
    Insulation voltage input / PE
    2 kV AC (type test)
    2 kV AC (routine test)
    Insulation voltage output / PE
    500 V DC (type test)
    Degree of protection
    IP20
    Protection class
    I (with PE connection)
    Mounting position
    horizontal DIN rail NS 35, EN 60715
    Assembly instructions
    alignable: horizontally 0 mm, vertically 50 mm
    Back to top
    Connection data, input
    Connection method
    Screw connection
    Conductor cross section solid min.
    0.2 mm²
    Conductor cross section solid max.
    2.5 mm²
    Conductor cross section flexible min.
    0.2 mm²
    Conductor cross section flexible max.
    2.5 mm²
    Conductor cross section AWG min.
    24
    Conductor cross section AWG max.
    14
    Stripping length
    9 mm
    Screw thread
    M2,5
    Back to top
    Connection data, output
    Connection method
    Screw connection
    Conductor cross section solid min.
    0.2 mm²
    Conductor cross section solid max.
    2.5 mm²
    Conductor cross section flexible min.
    0.2 mm²
    Conductor cross section flexible max.
    2.5 mm²
    Conductor cross section AWG min.
    24
    Conductor cross section AWG max.
    14
    Stripping length
    9 mm
    Screw thread
    M2,5
    Back to top
    Standards
    EMC requirements for noise immunity
    EN 61000-6-1
    EN 61000-6-2
    EMC requirements for noise emission
    EN 61000-6-3
    EN 61000-6-4
    Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
    Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
    Standard – Safety extra-low voltage
    EN 60950-1 (SELV)
    EN 60204 (PELV)
    Standard - Safe isolation
    DIN VDE 0100-410
    Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
    EN 50178
    Standard – Limitation of mains harmonic currents
    EN 61000-3-2
    Rail applications
    EN 50121-4
    Back to top
    Conformance/approvals
    UL approvals
    UL/C-UL listed UL 508
    UL/C-UL Recognized UL 60950-1
    Back to top
    EMC data
    Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
    Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
    Electrostatic discharge
    EN 61000-4-2
    Contact discharge
    6 kV (Test Level 3)
    Discharge in air
    8 kV (Test Level 3)
    Electromagnetic HF field
    EN 61000-4-3
    Frequency range
    80 MHz ... 1 GHz
    Test field strength
    10 V/m
    Frequency range
    1 GHz ... 2 GHz
    Test field strength
    10 V/m
    Frequency range
    2 GHz ... 3 GHz
    Test field strength
    10 V/m
    Comments
    Criterion A
    Fast transients (burst)
    EN 61000-4-4
    Input
    4 kV (Test Level 4 - asymmetrical)
    Output
    4 kV (Test Level 4 - asymmetrical)
    Signal
    2 kV (Test Level 3 - asymmetrical)
    Comments
    Criterion A
    Surge voltage load (surge)
    EN 61000-4-5
    Input
    2 kV (Test Level 3 - symmetrical)
    4 kV (Test Level 4 - asymmetrical)
    Output
    1 kV (Test Level 2 - symmetrical)
    2 kV (Test Level 3 - asymmetrical)
    Comments
    Criterion A
    Conducted interference
    EN 61000-4-6
    Frequency range
    0.15 MHz ... 80 MHz
    Voltage
    10 V (Test Level 3)
    Comments
    Criterion A
    Voltage dips
    EN 61000-4-11
    Back to top
    Environmental Product Compliance
    REACh SVHC
    Lead 7439-92-1
    China RoHS
    Environmentally Friendly Use Period = 25;
    For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
    Back to top
    Classifications
    ECLASS
    ECLASS 10.0.1
    27040701
    ECLASS 11.0
    27040701
    ECLASS 4.0
    27040700
    ECLASS 4.1
    27040700
    ECLASS 5.0
    27049000
    ECLASS 5.1
    27049000
    ECLASS 6.0
    27049000
    ECLASS 7.0
    27049002
    ECLASS 9.0
    27040701
    Back to top
    ETIM
    ETIM 2.0
    EC001039
    ETIM 3.0
    EC001039
    ETIM 4.0
    EC000599
    ETIM 6.0
    EC002540
    ETIM 7.0
    EC002540
    Back to top
    UNSPSC
    UNSPSC 6.01
    30211502
    UNSPSC 7.0901
    39121004
    UNSPSC 11
    39121004
    UNSPSC 12.01
    39121004
    UNSPSC 13.2
    39121004
    UNSPSC 18.0
    39121004
    UNSPSC 19.0
    39121004
    UNSPSC 20.0
    39121004
    UNSPSC 21.0
    39121004